New product
Transport fan of 3.0 kW in standard design, in a universal housing.
The universal housing allows the fan to be mounted in any outlet orientation.
Motor efficiency class: IE3 (Premium Efficiency).
Warning: Last items in stock!
Availability date:
Transport fans of the WMT series are designed for pneumatic transport of sawdust, shavings, flakes, granules, paper cuttings, dried, leather, plastics and other bulk substances of a similar nature.
Transport distance: up to 40 m (depending on the resistance of the pipeline).
The fan must not be used in explosive atmospheres or for transporting gases or substances threatening to explode.
The device is not suitable for pumping air containing corrosive or viscous contaminants.
WMT fans in the K variety are available in left and right versions (to be agreed by telephone). The version shown in the photos is produced as standard.
A WMT series catalog with technical data and mounting dimensions, as well as a 3D CAD drawing in STEP (.STP) format is available in the download section.
WMT fans are available in standard version (without additional marking) and in modified versions, described in the table below.
Modifications can be combined, e.g. WMT-5 WC H.
|
Modification designation |
Characteristics |
Example application |
|
WC |
Version with increased pressure |
Transport of plastics, granulates, ground waste |
|
H |
Rotor with double-layer blades with wear-resistant steel caps, wear-resistant steel casing wrap |
3-shift operation, recycling industry, transport of wood chips, high concentration of material |
|
PO |
Additional sealing to prevent vapor from the transported medium from reaching the motor bearings |
Transport of wet film flake, extraction of steam from pellet cooler, transport of washer waste |
|
PTO |
Additional sealing and heat rejection to limit heat transfer to the motor |
Pneumatic conveying at elevated temperatures (consider WMST or WMPT fans for more demanding applications) |
|
K |
Rectangular housing allowing installation in any orientation in space |
Built-in operation in a larger system or unusual pipeline layout |
| Nominal inlet diameter [mm] | 200 |
| Nominal outlet diameter [mm]. | 200 |
| Maximum pressure [Pa]. | 2200 |
| Maximum theoretical capacity [m3/h] | 5500 |
| Maximum capacity [m3/h] | 4150 |
| Typowy punkt pracy | 3000 m3/h, 1450 Pa |
| Rotor type | transportable, self-cleaning |
| Motor power [kW]. | 3.0 |
| Power supply | 3x400 V, 50 Hz |
| Engine speed [rpm]. | 2915 |
| Engine efficiency class | IE3 (Premium Efficiency) |
| In the price of the product | outlet adapter for connecting round pipe |
| The product does not include | power cord and switch |
| Weight [kg]. | about 60 |
| Joining method | spigot for sliding the pipe |
| Max. temperature of the pumped medium | 70 degrees Celsius |
| Work configuration | suction, discharge or suction and discharge |
CAD file (for import in programs such as Autodesk Inventor, AutoCad, SolidWorks, SolidEdge and others). For in-house use in transportation system design only.
DownloadFlow characteristics of WMT-2 fan. not applicable to fans with WC or HP designation.
Download